Under normal operating conditions the TMV thermostatic mixing valve will provide a very high level of performance. However, in some circumstances, when our maintenance plan is not followed, the following problems may arise.

 

Symptom  Cause  Corrective action 
Hot water at the cold taps a) Operation of the insert check valve is hindered: check valve is not sealing correctly.

b) Check valves not fitted.

Replace faulty check valve.
Fluctuating mixed water   temperature  a) Erratic supply temperatures at the inlet of the valve.

b) Starvation of the water supplies at the inlets of the valve.

c) Incorrect commissioning of the valve.

Restore inlet conditions within the limits of the valve.
Erratic flow of water from the valve  a) Insufficient water supplies.

b) Fluctuations in supply pressures/temperatures.

c) Adverse effect created by other draw off points on the system. 

Stabilize inlet supply conditions. 
No flow of water from the valve a) In-line filters blocked.

b) Insufficient supply pressures.

c) Debris obstructing valve operation.

Clean filters.

Restore inlet supplies.

Clean debris or scale from valve.

Valve does not shutoff when tested a) Installation not in accordance with our recommendations.

b) The minimum temperature differential not achieved.

c) Internal mechanism hindered by debris.

Install as outlined in the instructions.

Raise hot water temperature.

Clean debris or scale from valve.